SELFTESTBOARD
PARTICLE 2/10 with SELFTEST BOARD
The Self test board was designed to
check the CONAN connector of the Particle. Never use the self test board for
anything else.
Never
plug the self test board on a running particle, you can short circuit the
microprocessor
In order to use the self test board,
the appropriate code must be prepared in the particle. If the software has not
included the self test, it cannot be executed and the self test board may never
be plugged in!
If the code for the self test is
included (see selftest.c) you can always check the particle for correct and
error free connection. The procedure is as follows:
- Make
sure your particle carries the code to perform the self test
- turn
the particle off
- plug
the self test board and no other board into the particle
- turn
on the particle and watch the LEDs:
- the
blue LED flashed quickly 2 times to show that the self test board was
detected
- then
the blue LED stays on for a longer time to show that the self test is over
- then
the blue LED is turned off and on again for a good particle or turned off
and the red LED is turned on for a bad particle
- after
that, the red led blinks and the stack starts
- as
long as the self test board is plugged, the particle sends out the self
test report
- as
long as the self test board is plugged the particle will accept packets to
reset its ID with e.g. SetID in the particle analyser.